Lesson 3: Time Domain & Windowing

The Impulse Response (IR) is the "DNA" of your measurement. Understanding how to manipulate it via windowing is key to isolating direct sound.

Objective

To master the use of windowing to separate direct sound from room reflections.

Workflow

1. Inspect the Impulse Response: Locate the peak (the direct sound arrival).
2. Apply Windowing: Use a "Left" or "Right" window to isolate the direct sound from subsequent reflections.
What this means: An Impulse Response (IR) is a time-domain description of the system. The first spike is usually your direct sound. Everything after that is reflections and room decay. Windowing tells the FFT to ignore everything outside a specific time range, effectively "muting" the reflections.
Deeper Detail: Frequency-Dependent Windowing (FDW)

A fixed time window (e.g., 10ms) will have different frequency resolution at different frequencies. FDW solves this by making the window width vary: it uses a longer window for low frequencies (to maintain resolution) and a shorter window for high frequencies (to avoid aliasing/smearing). This is the gold standard for professional room analysis.

Quick Quiz: If you use a very short window to isolate the direct sound, what happens to your low-frequency resolution?
Show Answer
It degrades (you lose the ability to see low-frequency peaks/dips accurately).